Vorlader Logo

Blog categories

Comments

INDUSTRIAL APPLICATIONS
Office building
Production plant
Data Center
Food applications
Process air
PUBLIC BUILDING
Office building
Shopping mall
Public areas
HEALTH AND CARE
Health center
Septic treatment room
Treatment room
Surgary room
POOL DEHUMIDIFICATION
Public pool
Private pool
 
SKW Recu
SKW Compact
SKW Ruar
SKW Roto
SKW Pool / HP
SKW Compact Pool HP
      
   
  
     
     
     
      
   
    
    
      
   
    
     
     
      
     
     
Ausgewähltes ProduktAusgewähltes ProduktAusgewähltes ProduktAusgewähltes ProduktAusgewähltes ProduktAusgewähltes Produkt
GENERATIVE SOLUTIONS

SKW Compact

SKW Compact unit is made to be installed as a ready package. Although the unit can be split for installation at site.

Unit is designed for high heat recovery efficiency, up to 90%, with the lowest available pressure drop at the same time. Compact units are available up to 5000m3/h (Larger ones on request).  Counterflow unit can be selected in different categories adapting to the condition needed.

Normal counterflow unit is made from aluminum, special counterflow units can be equipped with nano foil material for latent energy recovery.

For swimming pool use the system will be equipped with epoxy coated heat recovery system.SKW Compact Pool use epoxy coated aluminium heat-exchangers.

Facilities: Private pool, Private house, Office small
Hotspot-Bild
SKW Compact Pool / HP video
shows how the device works in different seasons

Advantages

Advantages of Skawen’s ventilation and dehumidifying devices for swimming pool comfort include:
– Energy-efficient and sustainable
– Customizable air connections
– Cost-effective and efficient heat recovery options
– Innovative and hygienic design
– Space-efficient and compact

We set trends and inspire others

Key Features

  • Recirculation of exhaust air and supply air with simultaneous constant mixing of outdoor air
  • Controllable heat pump for energy recovery from the exhaust air
  • Variable outside air volume flow for dehumidification with constant exhaust air and supply air volume flow at the same time
  • Heating register for reheating the supply air with low flow and return temperatures
  • Temperature and humidity control
  • The control cabinet can be mounted on the device or remotely on the wall.

Options

  • With pool water condenser
  • Plastic heat exchanger

High quality housing

  • Acoustically insulated panels for low acoustic levels
  • TB2, T2, L1 [M], D1 [M]
  • Robust design with 30% lighter weight
  • Duct connections on the side or on top, adjustable on site
Basics of Skawen ventilation technology

Dehumidifying devices for private
and public swimming pools

The ventilation and dehumidifying devices provided by Skawen are the result of decades of experience in the development and production of ventilation units.

The most important features are maximum economic efficiency in operation and sustainability in terms of long life-cycle and resource conservation.

Compact systems with various functional features are used for comfort in swimming pools. These features enable simple and precise implementation when installing the systems in new buildings or at renovations.

Due to the possibility to configure the air connections the devices are also space efficient.

The devices are usually set up in the technical room and connected to the swimming pool through air ducts (supply and exhaust air).

The air ducts for outside and exhaust air are led outside. It should be noted here that the exhaust air is led away from the house in order to avoid condensation on the building structure.

In the swimming pool, the supply air is brought in via air outlets in front of the windows.

The exhaust air should be extracted at several points in the room in accordance with VDI 2089.

Several levels of heat recovery can be used in swimming pools. During the planning phase of a project, the right device concept can be chosen by asking about how it will be used. More complex technology is not always more economical!

With classic dehumidifiers, if the pool is covered for more than 22 hours a day, for example, a heat pump does not make sense, as evaporation is reduced to a fraction.

With devices from Skawen, the heat is reclaimed with the help of a recuperator and, if you want, a heat pump further down the line. The heat pump is output-regulated and is used exclusively for heat recovery.

The housing of the ventilation unit consists of anodized,
self-supporting thermally separated aluminum profiles.

The double-walled panels (50mm) are filled with non-combustible mineral thermal insulation, at least class A (DIN4102). The 3 mm thick sheet is filled with a 2.8 mm thick sound-absorbing compound and is therefore already very quiet as standard.

The inner and outer sheets are thermally separated from each other.

For maintenance purposes, the devices are equipped with removable panels with handles or wing doors, depending on the unit size and type.

The energy recovery system of the plate heat exchanger is completely built into the air handling unit and has a condensate collecting tray as well as an integrated bypass flap system for temperature and demand-dependent frost protection control.

The filter system, which is so important for hygiene, is designed in accordance with the CEN EN 779 standard in order to be able to keep a constant maximum air quality in the room. This is continuously monitored by the control system integrated in the unit.

State-of-the-art eC fans of the latest generation regulate the required air output for supply and exhaust air as required.

The control and regulation of the device takes place via a DDC system with self-optimizing mode of operation for the removal of moisture from the swimming pool.

Optionally, the systems can be equipped with a highly efficient controllable heat pump for energy recovery and a pool water condenser.

When operating with a heat pump, energy is recovered from the exhaust air in a regulated manner that is adapted to the operation. Economical operation of the heat pump can only be guaranteed through this operating mode.

Benefits

  • Heated, ventilated and dehumidified
  • Energy-saving eC fans
  • Corrosion-resistant design
  • ERP compliant
  • Continuous regulation for the removal of moisture
  • Optionally with plastic heat exchanger
  • Integrated control and regulation
.portfolio_single .dfd-inside-gallery-wrap {margin: -0px;}.portfolio_single .dfd-inside-gallery-wrap > article > a.dfd-lightbox-link {display: block; padding: 0px;}#layout.single-folio > .row.full-width .dfd-content-wrap.dfd-portfolio_single > article.portfolio .media-section.twelve.columns .media-cover,#layout.single-gallery > .row.full-width .dfd-content-wrap.dfd-gallery_single > article.gallery_single .media-section .media-cover {padding: 0px;}#main-content .dfd-content-wrap {margin: 0px;} #main-content .dfd-content-wrap > article {padding: 0px;}@media only screen and (min-width: 1101px) {#layout.dfd-portfolio-loop > .row.full-width > .blog-section.no-sidebars,#layout.dfd-gallery-loop > .row.full-width > .blog-section.no-sidebars {padding: 0 0px;}#layout.dfd-portfolio-loop > .row.full-width > .blog-section.no-sidebars > #main-content > .dfd-content-wrap:first-child,#layout.dfd-gallery-loop > .row.full-width > .blog-section.no-sidebars > #main-content > .dfd-content-wrap:first-child {border-top: 0px solid transparent; border-bottom: 0px solid transparent;}#layout.dfd-portfolio-loop > .row.full-width #right-sidebar,#layout.dfd-gallery-loop > .row.full-width #right-sidebar {padding-top: 0px;padding-bottom: 0px;}#layout.dfd-portfolio-loop > .row.full-width > .blog-section.no-sidebars .sort-panel,#layout.dfd-gallery-loop > .row.full-width > .blog-section.no-sidebars .sort-panel {margin-left: -0px;margin-right: -0px;}}#layout .dfd-content-wrap.layout-side-image,#layout > .row.full-width .dfd-content-wrap.layout-side-image {margin-left: 0;margin-right: 0;}
    • I want